Instrumentation Basics
Instrumentationis a technology of measurement whichserves sciences, engineering, medicine and etc.
Measurementis the process of determining theamount, degree or capacity by comparison with theaccepted standards of the system units being used.
Instrument is a device for determining the value ormagnitude of a quantity or variable.
Mechanical instrumentis based on mechanicalprinciples for its measurement functions
Electronic instrumentis based on electrical orelectronic principles for its measurement functions
-
8/13/2019 RM Unit 1 Instrunents
2/29
Instrumentation Schemes/Functions
The 3 basic functions of instrumentation :-
Indicating visualize the process/operation
Recording observe and save the measurement reading
Controlling to control measurement and process
-
8/13/2019 RM Unit 1 Instrunents
3/29
Basic components in a measurement system
Basic components in a measurement system are shown below:
It is also important to mention that a power supply is an important
element for the entire system.
Amplification and Conditioning
-
8/13/2019 RM Unit 1 Instrunents
4/29
PERFORMANCE CHARACTERISTICS
Performance Characteristics - characteristics that show theperformance of an instrument.
Eg: accuracy, precision, resolution, sensitivity.
Allows users to select the most suitable instrument for a specificmeasuring jobs.
Two basic characteristics : Static measuring a constant process condition.
Static characteristics refer to the comparisonbetween steady output and ideal output when theinput is constant.
Dynamic - measuring a varying process condition.
Dynamic characteristics refer to the comparisonbetween instrument output and ideal output when theinput changes.
-
8/13/2019 RM Unit 1 Instrunents
5/29
Static Characteristics
Accuracy Accuracy is the ability of an instrument to
show the exact reading.
Always related to the extent of the wrong
reading/non accuracy. Normally shown in percentage of error which
of the full scale reading percentage.
the degree of exactness (closeness) of
measurement compared to the expected(desired) value.
-
8/13/2019 RM Unit 1 Instrunents
6/29
Static Characteristics
Precision
An equipment which is precise is notnecessarily accurate.
Defined as the capability of an instrumentto show the same reading when used eachtime (reproducibility of the instrument).
a measure of consistency or repeatability of
measurement, i.e successive reading do notdiffer.
-
8/13/2019 RM Unit 1 Instrunents
7/29
Static Characteristics
Example :X : result
Centre circle : true value
XXX
XXXX
XXX
XXX
XXX
X X
X
xxHigh accuracy, high precision
Low accuracy, high precision
Low accuracy, low precision
-
8/13/2019 RM Unit 1 Instrunents
8/29
Static Characteristics
Tolerance
Defined as the maximum error expectedin an instrument.
Closely related to accuracy of anequipment where the accuracy of anequipment is sometimes referred to inthe form of tolerance limit.
Explains the maximum deviation of anoutput component at a certain value.
-
8/13/2019 RM Unit 1 Instrunents
9/29
Static Characteristics
Range of Span
Defined as the range of reading betweenminimum value and maximum value for themeasurement of an instrument.
Has a positive value e.g..:The range of span ofan instrument which has a reading range of 100C to 100 C is 200 C.
-
8/13/2019 RM Unit 1 Instrunents
10/29
Static Characteristics
Bias Constant error which occurs during the
measurement of an instrument.
This error is usually rectified through calibration.
Example :
A weighing scale always gives a bias reading. Thisequipment always gives a reading of 1 kg evenwithout any load applied. Therefore, if A with aweight of 70 kg weighs himself, the given reading
would be 71 kg. This would indicate that there is aconstant bias of 1 kg to be corrected.
-
8/13/2019 RM Unit 1 Instrunents
11/29
Static Characteristics
Sensitivity
ratio of change in the output (response) ofinstrument to a change of input or measuredvariable.
Sensitivity (K) = i: change in output; i : change in input
Example 1:
The resistance value of a Platinum ResistanceThermometer changes when the temperature increases.
Therefore, the unit of sensitivity for this equipment isOhm/C.
-
8/13/2019 RM Unit 1 Instrunents
12/29
Static Characteristics
Linearity Maximum deviation from linear relation between input
and output.
The output of an instrument has to be linearly
proportionate to the measured quantity. Normally shown in the form of full scale percentage (%
fs).
The graph shows the output reading of an instrumentwhen a few input readings are entered.
Linearity= maximum deviation from the reading of xand the straight line.
-
8/13/2019 RM Unit 1 Instrunents
13/29
Static Characteristics
Linearity
Output
Readings
Measured Quantity
-
8/13/2019 RM Unit 1 Instrunents
14/29
Static Characteristics
Expected value the design value or the most probable value
that expect to obtain.
Error the deviation of the true value from the desired value.
Threshold The minimum limit of the input reading is
threshold. When the reading of an input is increased from zero, the
input reading will reach a certain value before change
occurs in the output.
-
8/13/2019 RM Unit 1 Instrunents
15/29
Dynamic Characteristics
Dynamic measuring a varying process condition.
Instruments rarely respond instantaneously to changes in themeasured variables due to such things as mass, thermalcapacitance, fluid capacitance or electrical capacitance.
Pure delay in time is often encountered where the instrument
waits for some reactionto take place. Such industrial instruments are nearly always used for
measuring quantities that fluctuate with time.
Therefore, the dynamic and transient behavior of theinstrument is important.
-
8/13/2019 RM Unit 1 Instrunents
16/29
The dynamic behavior of an instrument isdetermined by subjecting its primary element(sensing element) to some unknown andpredetermined variations in the measured quantity.
The three most common variations in the measuredquantity: Step change
Linear change
Sinusoidal change
Dynamic Characteristics
-
8/13/2019 RM Unit 1 Instrunents
17/29
Step change-in which the primary element is subjected to an
instantaneous and finite change in measured variable.
Linear change-in which the primary element is following the
measured variable, changing linearly with time.
Sinusoidal change-in which the primary element follows ameasured variable, the magnitude of which changes in
accordance with a sinusoidal function of constant amplitude.
Dynamic Characteristics
-
8/13/2019 RM Unit 1 Instrunents
18/29
DYNAMIC CHARACTERISTICS
Step Input
Sudden change in input signal from steadystate.
The output signal for this kind of input isknown as transient response.
Input
Time
-
8/13/2019 RM Unit 1 Instrunents
19/29
DYNAMIC CHARACTERISTICS
Ramp Input The signal changes linearly.
The output signal for ramp input is
ramp response.
Input
Time
-
8/13/2019 RM Unit 1 Instrunents
20/29
DYNAMIC CHARACTERISTICS
Sine- wave Input
The signal is harmonic.
The output signal is frequency response.
Input
Time
-
8/13/2019 RM Unit 1 Instrunents
21/29
Dynamic Characteristics
The dynamic performance characteristics of aninstrument are:
Speed of response- The rapiditywith which aninstrument responds changes in measured quantity.
Dynamic error-The difference between the true andmeasured value with no static error.
Lag delay in the response of an instrument tochanges in the measured variable.
Fidelity the degree to which an instrument indicatesthe changesin the measured variable without dynamicerror (faithful reproduction).
-
8/13/2019 RM Unit 1 Instrunents
22/29
Fidelity of Instruments
Fidelity- truthfulness
Error-Actual Vs Expected
Types of Errors and Reasons
Data Collection using Computer Systems
Role of DSP in Correction
-
8/13/2019 RM Unit 1 Instrunents
23/29
TYPES OF STATIC ERROR
Types of static error
1) Gross error/human error
2) Systematic Error3) Random Error
-
8/13/2019 RM Unit 1 Instrunents
24/29
1) Gross Error cause by human mistakes in reading/using instruments
may also occur due to incorrect adjustment of the instrument and thecomputational mistakes
cannot be treated mathematically
cannot eliminate but can minimize
Eg: Improper use of an instrument.
This error can be minimized by taking proper care in reading andrecording measurement parameter.
In general, indicating instruments change ambient conditionsto someextent when connected into a complete circuit.
Therefore, several readings (at threereadings) must be taken to minimize
the effect of ambient condition changes.
TYPES OF STATIC ERROR
-
8/13/2019 RM Unit 1 Instrunents
25/29
TYPES OF STATIC ERROR (cont)
2) Systematic Error
- due to shortcomings of the instrument (such as
defective or worn parts, ageing or effects of the
environment on the instrument)
In general, systematic errors can be subdivided into static anddynamic errors.
Static caused by limitationsof the measuring device or the
physical laws governing its behavior.
Dynamic caused by the instrument not responding very fast
enough to follow the changes in a measured variable.
-
8/13/2019 RM Unit 1 Instrunents
26/29
- 3 types of systematic error :-
(i) Instrumental error
(ii) Environmental error
(iii) Observational error
TYPES OF STATIC ERROR (cont)
-
8/13/2019 RM Unit 1 Instrunents
27/29
TYPES OF STATIC ERROR (cont)
(i) Instrumental error
- inherent while measuring instrument because of
their mechanical structure (eg: in a DArsonval meter,
friction in the bearings of various moving component,irregular spring tension, stretching of spring, etc)
- error can be avoid by:
(a) selecting a suitable instrument for the particular
measurement application
(b) apply correction factor by determining
instrumental error(c) calibrate the instrument against standard
-
8/13/2019 RM Unit 1 Instrunents
28/29
TYPES OF STATIC ERROR (cont)
(ii) Environmental error- due to external condition effecting the
measurement including surrounding area conditionsuch as change in temperature, humidity,
barometer pressure, etc- to avoid the error :-
(a) use air conditioner(b) sealing certain component in the instruments(c) use magnetic shields
(iii) Observational error
- introduce by the observer
- most common : parallax error and estimation error (while reading
the scale)
- Eg: an observer who tend to hold his head too far to the leftwhile reading the position of the needle on the scale.
-
8/13/2019 RM Unit 1 Instrunents
29/29
TYPES OF STATIC ERROR (cont)
3) Random error
- due to unknown causes, occur when all systematic
error has accounted
- accumulation of small effect, require at high degree of
accuracy- can be avoid by
(a) increasing number of reading
(b) use statistical means to obtain best approximation
of true value