Introducing the Model 560 ESCA/SAM. A complete surface chemistry laboratory. Most analytical and research laboratories face a wide range of surface chemistry problems, so multiple surface analysis tech- niques are needed to do the job. That's why PHI®designed the new Model 560 ESCA/SAM for opti- mum, computerized ESCA and SAM performance. Each tech- nique offers unique advantages for different types of samples. Used together, they provide a more detailed analysis and a higher probability of getting the correct answer to a problem. PHI's new SIMS Π accessory can also be added to the Model 560. Software for the integral computer system covers all of these tech- niques practically and efficiently. Features include: Maximum Sample Throughput A sample introduction system, combined with the integral com- puter system, ensures the highest sample throughput and lowest cost per sample. High ESCA Count Rates A new, high flux, dual anode x-ray source in combination with a cylindrical-mirror analyzer pro- vides higher count rates for excel- lent ESCA sensitivity. Improved SAM Performance Redesigned coaxial electron gun provides beam diameters below 2 Mm for improved SAM resolution and SEM imaging. Total System Automation Computerized system control and data manipulation increase sam- ple throughput. Available software provides maximum spectral in- formation for a more thorough analysis. Optional Transfer Vessel A special transfer vessel allows sample pre-treatment and trans- fer to the analysis chamber without exposure to outside atmosphere. For More Information To find out how this unique new instrument can help you solve your materials problems, contact the office nearest you. Minneapolis, MN, USA: Perkin- Elmer, Physical Electronics Div., 6509 Flying Cloud Drive, Eden Prairie, MN, USA, 55344; Tele- phone (612) 941-5540. Munich, West Germany: Perkin- Elmer GmbH, Physical Electron- ics Div., Bahnhofstrasse 30, D-8011 Vaterstetten, Germany. Hong Kong: Perkin-Elmer, Sur- face Sciences Div., 303 Fourseas Building, 208-212 Nathan Road, Tsimshatsui, Kowloon, Hong Kong. Japan: Contact Ulvac Corpora- tion, Tokyo. Physical Electronics CD PERKIN-ELMER Responsive Technology CIRCLE 170 ON READER SERVICE CARD

Transcript of PERKIN-ELMER

Page 1: PERKIN-ELMER

Introducing the Model 5 6 0 ESCA/SAM. A complete surface chemistry laboratory.

Most analytical and research laboratories face a wide range of surface chemistry problems, so multiple surface analysis tech­niques are needed to do the job. That's why PHI®designed the new Model 560 ESCA/SAM for opti­mum, computerized ESCA and SAM performance. Each tech­nique offers unique advantages for different types of samples. Used together, they provide a more detailed analysis and a higher probability of getting the correct answer to a problem. PHI's new SIMS Π accessory can also be added to the Model 560. Software for the integral computer system covers all of these tech­niques practically and efficiently. Features include:

Maximum Sample Throughput A sample introduction system, combined with the integral com­puter system, ensures the highest

sample throughput and lowest cost per sample.

High ESCA Count Rates A new, high flux, dual anode x-ray source in combination with a cylindrical-mirror analyzer pro­vides higher count rates for excel­lent ESCA sensitivity.

Improved SAM Performance Redesigned coaxial electron gun provides beam diameters below 2 Mm for improved SAM resolution and SEM imaging.

Total System Automation Computerized system control and data manipulation increase sam­ple throughput. Available software provides maximum spectral in­formation for a more thorough analysis.

Optional Transfer Vessel A special transfer vessel allows sample pre-treatment and trans­fer to the analysis chamber without exposure to outside atmosphere.

For More Information To find out how this unique new instrument can help you solve your materials problems, contact the office nearest you.

Minneapolis, MN, USA: Perkin-Elmer, Physical Electronics Div., 6509 Flying Cloud Drive, Eden Prairie, MN, USA, 55344; Tele­phone (612) 941-5540.

Munich, West Germany: Perkin-Elmer GmbH, Physical Electron­ics Div., Bahnhofstrasse 30, D-8011 Vaterstetten, Germany.

Hong Kong: Perkin-Elmer, Sur­face Sciences Div., 303 Fourseas Building, 208-212 Nathan Road, Tsimshatsui, Kowloon, Hong Kong.

Japan: Contact Ulvac Corpora­tion, Tokyo.