Perl in Dung An

download Perl in Dung An

of 159

Transcript of Perl in Dung An

Perlindungan IKRAM 1PERLINDUNGAN PERLINDUNGANOleh: Mohd Zhahir b Othman Keiuteraan Elektrik .Perlindungan IKRAM 2TU1UAN PERLINDUNGAN TU1UAN PERLINDUNGAN Menyelamatkan nyawa manusia & haiwan Mengelakkan kecederaan kepada manusia Mengelakkan kemusnahan harta benda Mengelakkan kerosakan mesen-mesen elektrik Mengelakkan kerugian Image dan reputasi sesebuah organisasiPerlindungan IKRAM 3CIRI CIRI- -CIRI PERLINDUNGAN CIRI PERLINDUNGAN Bertindak pantas tetapi hanya apabila betul-betul perlu SensitiI tetapi pada keadaan yang perlu Stabil Mempunyai kepemilihan (selectability) Keboleharapan (reliability) Boleh membezakan diantara temporary overload dan real overloadPerlindungan IKRAM 4PEMBEZALAYANAN PEMBEZALAYANAN(DISCRIMINATION) (DISCRIMINATION)Mengadakan perbezaan tahap arus ataumasa atau kedua-duanya sekali pada setiapperingkat litar supaya bahagian yangmengalami kerosakandapat dihadkanagaria tidak melibatkan bahagian lain. Pembezalayanan Arus Pembezalayanan Masa Pembezalayanan Arus dan MasaPerlindungan IKRAM 5DISCRIMINATION DISCRIMINATIONBhg ini saia Bhg ini saiatrip tripPerlindungan IKRAM 6DISCRIMINATION DISCRIMINATION(CURRENT) (CURRENT)Perlindungan IKRAM 7Perlindungan IKRAM 8DISCRIMINATION CURRENT DISCRIMINATION CURRENTPerlindungan IKRAM 91ENIS 1ENIS- -1ENIS PERLINDUNGAN 1ENIS PERLINDUNGAN Arus lebih (litar pintas) Beban lebih (kW berlebihan) Bocor ke bumi (earth leakage) Rosak ke bumi (earth Iault) Kilat dan Voltage Surge (lightning) Lampau panas (overheating) Single phasing Reverse phase rotation Perlindungan IKRAM 10ARUS LEBIH ARUS LEBIH Berlaku litar pintas, nilai arus dalamkiloampiar (kA) Arussebesar ini tidakmampuditanggungoleh litar walaupun untuk iangka masa yangpendek pun (1 saat) dan ia akan merosakanpemasangan atau peralatan Pemutuslitar hendaklahmemutuskanlitarsecepat yang mungkin ( 1 saat)Perlindungan IKRAM 11BEBAN LEBIH BEBAN LEBIH Disebabkan beban kilowatt yang berlebihandari yang telah dikadarkan (rated) Tiada kerosakan pada litar Nilai arusnya tidak terlalu tinggi (150) Beban lebih yang kecil dan berbentuksementara boleh ditanggung oleh litar tanpakesan yang memudaratkanPerlindungan IKRAM 12HAD BEBAN LEBIH HAD BEBAN LEBIHBEBAN DLM DARI BEBAN DIHADKANMASA100 CONTINUOUS120 WITHIN 5 MINUTES150NOT MORE THAN 1 SECONDPerlindungan IKRAM 13BOCOR KE BUMI BOCOR KE BUMI Terdapat arus mengalir ke bahagian-bahagian logam yang dibumikandisebabkan penebatan yang telah lemah Nilai arusnya kecil, lazimnya dihadkankepada tidak lebih 10 peratus dari aruskadaranPerlindungan IKRAM 14ROSAK KE BUMI ROSAK KE BUMI Samaseperti litar pintas tetapi iaberlakudiantara konduktor Iasa atau neutral kebumi Arus kerosakan dalam kAPerlindungan IKRAM 15ALAT PERLINDUNGAN ALAT PERLINDUNGAN Fius MCB (Miniature Circuit Breaker) RCCB/ELCB (Residual Current C.Breaker) RCBO (RCCB with Over current protection) MCCB (Molded Case Circuit Breaker) ACB (Air Circuit Breaker)Perlindungan IKRAM 16PRINSIP KER1A PRINSIP KER1A Haba (Iius dan thermal overload relay) Magnet (MCB, MCCB, RCCB) Haba & Magnet (MCCB ienis tertentu)Perlindungan IKRAM 17FIUS FIUSAlat perlindungan paling awal dicipta yangmenggunakan prinsip apabila arus mengalirhabaakanterhasil danhabayangbanyakhasil dari arus yang tinggi bolehmeleburkanelemenIius danmemutuskanbekalanPerlindungan IKRAM 181ENIS 1ENIS- -1ENIS FIUS 1ENIS FIUS Fius dawai Fius katrii (catridge Iuse) Fius HRC (high rupturing capacity) atau HBC (high breaking capacity)Perlindungan IKRAM 19FIUS DAWAI FIUS DAWAI Murah Dalam bentuk gelong standard 5A,10A,15A Tiada melting point tertentu Apabilaterbakar merosakkanIusebase&carrier akibat arka yang kuat Sesuai untuk pole Iuse, Iius tiang lampuialan dimana risiko kebakaran rendahPerlindungan IKRAM 20FIUS DAWAI FIUS DAWAIPerlindungan IKRAM 21FIUS DAWAI FIUS DAWAIPerlindungan IKRAM 22FIUS KATRI1 FIUS KATRI1 Elemen Iius berada didalambekas kacalutsinar dan logampenutup dikedua-duahuiungnya. Elemen Iius boleh dilihat Untuk kadaran arus yangkecilbagivoltan240V, kadaran yang lebih untuk 12V DC. Banyak digunakan di dalam peralatanelektrik dan kenderaan.Perlindungan IKRAM 23FIUS FIUSKATRIJ KATRIJPerlindungan IKRAM 24FIUS HRC FIUS HRC Kadaran kA nya tinggi sehingga 100kA Terdapat melting point ElemenIius berada didalam arc quenchingpowder (serbok silicon halus) Bahagian luar dibuat dari bahan ceramikyang kukuh (porcelain) TelingaIius(tag)dikedua-duahuiungIiusdibina kukuhPerlindungan IKRAM 25HRC FUSE CROSS SECTION HRC FUSE CROSS SECTIONPerlindungan IKRAM 26FIUS HRC FIUS HRC(Centre tag (Centre tagDan Off tag) Dan Off tag)Perlindungan IKRAM 27FIUS HRC FIUS HRCEMPATSEGI EMPATSEGIPerlindungan IKRAM 28RCCB/ELCB RCCB/ELCB Residual current circuit breakermenggunakan prinsip keseimbangan medanmagnet diantara pengalir hidup dan neutral(ienis satu Iasa) atau keseimbangan medan-medandidalamsistemtigaIasa(ienistigaIasa). Ia memberikan perlindungan bocor ke bumi/ rosak ke bumi dan tidak memberiperlindungan arus lebih atau beban lebih.Perlindungan IKRAM 29RCCB RCCBPerlindungan IKRAM 30RCCB RCCBPerlindungan IKRAM 31RCCB RCCBPerlindungan IKRAM 32KADARAN RCCB KADARAN RCCB Arus beban 40A, 63A, 100A, 1ph, 3ph Kepekaan 10mA, 30mA, 100mA, 300mA 10mA (kidding machine) 30mA (litar soket outlet 13A) 100mA (litar lampu DB satu Iasa) 300mA (litar lampu DB tiga Iasa)Nota: RCCB tiga Iasa sudah tidak digalakkan lagi penggunaannya.Perlindungan IKRAM 33RCCB 10mA RCCB 10mAPerlindungan IKRAM 34RCCB RCCB63A. 30mA 63A. 30mAPerlindungan IKRAM 35Perlindungan IKRAM 36SOLID EARTHING SOLID EARTHING Bermakna perlindungan yang tidakmenggunakanRCCB/ELCBdengansyaratrintangan pembumian adalah baik danpemasangantiada kemungkinandihampirioleh kanak-kanak dan orang awamyangtiada pengetahuan khusus mengenai bahayaelektrik. Hanya Iius atau MCB sahaiadigunakan untuk tuiuan perlindungan.Perlindungan IKRAM 37EARTH FAULT CURRENT FLOW EARTH FAULT CURRENT FLOWPerlindungan IKRAM 38SISTEM PEMBUMIAN SISTEM PEMBUMIAN CPCcircuit protective conductor Terminal bumi DB Earthing conductor Earthing electrode Equipotential bondingPerlindungan IKRAM 39BAHAGIAN BAHAGIANBAHAGIAN BAHAGIANSISTEM SISTEMPEMBUMIAN PEMBUMIANPerlindungan IKRAM 40SAIZ SAIZ- -SAIZ SAIZPENGALIR PENGALIRBUMI BUMIPerlindungan IKRAM 41ELEKTROD ELEKTRODBUMI BUMIPerlindungan IKRAM 42EARTH CHAMBER EARTH CHAMBERPerlindungan IKRAM 43EARTH CLIP EARTH CLIPPerlindungan IKRAM 44EARTH EARTHBARBAR CLIP CLIPPerlindungan IKRAM 45TEST TESTPOINT POINTPerlindungan IKRAM 46MINIATURE CIRCUIT BREAKERMINIATURE CIRCUIT BREAKER (MCB) (MCB) Ia dicipta untuk menggantikan Iius sebab Iiusperlu ditukar setiap kali ianya terbakar. Menggunakan prinsip medan magnet Tindakannya pantas, sesuai untuk arus lebih Kadaran kA tidak tinggi Terdapat gelong bersiri dengan konduktormembawa arus beban Apabila terpelantik disebabkan arus lebih ia bolehdi RESET dan digunakan semula tanpa perlumenggantikannya dengan yang baru. Untuk kegunaan satu Iasa, sehingga 32APerlindungan IKRAM 47MINIATURE CIRCUIT BREAKER MINIATURE CIRCUIT BREAKERPerlindungan IKRAM 48MCB MCBPerlindungan IKRAM 49Perlindungan IKRAM 50MOULDED CASE CIRCUIT BREAKERMOULDED CASE CIRCUIT BREAKER (MCCB) (MCCB) Prinsip asas sama dengan MCB Untuk kegunaan tiga Iasa, sehingga 1600A Menggantikan Iius suis atau ACB Mempunyai shunt trip coil untuk earth Iault trip dan iuga overload trip Kadaran kA sehingga 50kA Boleh ditatah menggunakan gegantiPerlindungan IKRAM 51MCCB MCCBPerlindungan IKRAM 52AIR CIRCUIT BREAKER (ACB) AIR CIRCUIT BREAKER (ACB) ACByangasas adalahsebuahpengasingsahaia, tidak boleh trip sendiri kecualidipasang shunt trip coil yang disambungkankepada geganti. Mengandungi 3 atau 4 kutub Diperbuat dari logamolehituiakuat dankukuh berbanding dengan MCCB Kadaran kA sehingga 50kA Kadaran arus dari 600A hinggalah 8000APerlindungan IKRAM 53ACB ACBPerlindungan IKRAM 54SHUNT TRIP COIL SHUNT TRIP COIL Gelong kecil yang menarik mechanismpemutus litar untuk terpelantik. Mendapat bekalandari busbar ataubaterimelalui kawalan trip contact geganti. Kadaran voltan: 240AC, 30V DC Short time ratingPerlindungan IKRAM 55SHUNT TRIP COIL SHUNT TRIP COILPerlindungan IKRAM 56ALATUBAH ARUS (C.T) ALATUBAH ARUS (C.T) Menggunakan prinsip alatubah untukmendapatkan arus yang kecil tetapi dengannisbah tertentu supaya sesuai dengankadaran geganti atau meter. Mengelakkan sambungan terus kepadabusbar supaya lebih selamat dan mudahdikendalikan.Perlindungan IKRAM 57CURRENT TRANSFORMER CURRENT TRANSFORMERPerlindungan IKRAM 58CURRENT TRANSFORMER CURRENT TRANSFORMERPerlindungan IKRAM 59CURRENT CURRENTTRANSFORMER TRANSFORMERPerlindungan IKRAM 60CURRENT CURRENTTRANSFORMER TRANSFORMERPerlindungan IKRAM 61Perlindungan IKRAM 62CT & RELAY CONNECTION FOR HT INSTALLATION CT & RELAY CONNECTION FOR HT INSTALLATION2 O/C & 1 E/F 2 O/C & 1 E/FPerlindungan IKRAM 63Z C.T Z C.TBUSBAR BUSBARPerlindungan IKRAM 64Z C.T Z C.TPerlindungan IKRAM 65Z C.T Z C.TBUSBAR BUSBARPerlindungan IKRAM 661ENIS ALATUBAH ARUS 1ENIS ALATUBAH ARUS Jenis Perlindungansambunganke geganti Jenis Pengukuransambungan keammeter, kWmeter, kWhmeter,P.F meter, P.F regulator.Perlindungan IKRAM 67KLAS ALATUBAH ARUS KLAS ALATUBAH ARUS Kelas Perlindungankelas 5P dan 10P Kelas Pengukurankelas 0.1 hingga 5Perlindungan IKRAM 68KLAS C.T PERLINDUNGAN KLAS C.T PERLINDUNGAN 5P5, 5P10, 5P15, 5P20, 5P30 10P5, 10P10, 10P15, 10P20, 10P30 First numbercomposite error / ALF (accuracy limit Iactor) Pprotection type Second numbermultiple oI Iault currentPerlindungan IKRAM 69KLAS C.T PENGUKURAN KLAS C.T PENGUKURAN 0.1 (Lab / calibration Iunction) 0.2 (Accurate revenue application) 0.5 (Revenue application) 1.0 (Normal application) 3.0 (Non revenue application) 5.0 (Estimate reading)Perlindungan IKRAM 70KETEPATAN C.T KETEPATAN C.TKlasCurrent error at rated primary current ()Accuracy Limit Factor (ALF) / Composit Error5P 1510P3 10Perlindungan IKRAM 71BURDEN C.T BURDEN C.T KuasaalatubaharusdalamVAkadaranstandard ialah 2.5, 5, 7.5, 10, 15, 30VA. Beban tanggungan ialah wayerpenyambungan ke geganti atau meter,gelong didalam geganti atau meter. Mengatasi susut voltan pada kabelsambungan.Perlindungan IKRAM 72U1IAN U1IAN- -U1IAN C.T U1IAN C.T Uiian Nisbah (Primary Iniection) Uiian Kemagnetan Uiian Kekutuban (Polarity Test)Perlindungan IKRAM 73PRIMARY IN1ECTION TEST PRIMARY IN1ECTION TESTPerlindungan IKRAM 74U1IAN KEKUTUBAN U1IAN KEKUTUBANPerlindungan IKRAM 75MAGNETISATION TEST MAGNETISATION TESTPerlindungan IKRAM 76MAGNETISATION MAGNETISATIONCURVE CURVEPerlindungan IKRAM 77GEGANTI GEGANTISatu komponen perlindungan yangberIungsi untuk menentukan pada tahapkerosakan tertentu yang memerlukanpemutuslitarterpelantik. Tahapkerosakanadalah nilai tatahan yang di set terlebihdahulu. Trip contact akan tertutup danmenyalurkan bekalan kepada shunt trip coiluntuk membuka pemutus litar.Perlindungan IKRAM 78GEGANTI BEBAN LEBIH GEGANTI BEBAN LEBIH Selalunya digunakan untuk motor. Biasanyamempunyai dua ciri-ciri yang berbezadimana ia bolehmenampungbebanlebihyang tinggi semasa motor masih seiuk Cold or starting curveduring starting Hot or running curvewhen motor is hot,usuallyaIter beingonIull loadIor morethan 30 minutesPerlindungan IKRAM 79GEGANTI ARUS LEBIH GEGANTI ARUS LEBIH Can have any oI the Iollowing characteristics: Inverse deIinite minimum time (IDMT) DeIinite timehigh set with a time delay Instantaneousoperate in about 20-40ms Microprosessor relays usually combine all the three characteristicsPerlindungan IKRAM 80PRINSIP GEGANTI PRINSIP GEGANTI Magnetic eIIect Thermal eIIect Magnetic and Thermal eIIectPerlindungan IKRAM 811ENIS 1ENIS- -1ENIS GEGANTI 1ENIS GEGANTI Geganti sertamerta (instantenous relay) Geganti lewat masa (IDMT relayInverse DeIinite Minimum Time)Perlindungan IKRAM 821ENIS 1ENIS- -1ENIS GEGANTI 1ENIS GEGANTI Attracted armature relay Induction relay Thermal relay Mechanical relay Static relayPerlindungan IKRAM 83ATTRACTED ARMATURE RELAY ATTRACTED ARMATURE RELAY Comprises an iron-cored electromagnet thatattracts movable armature, which is hingedto operate relay contacts Instantaneous operation ACrelays have split magnetic pole withshading loop Iitted on one halI oI the pole toprevent relay chatteringPerlindungan IKRAM 84INDUCTION RELAYS INDUCTION RELAYS Comprises an electromagnetic systemsimilar to induction kWh meter Hastwoelectromagnetswithrotatingdiscin between two magnets. Can be energisedIrom a single or two diIIerent inputs Widely used Ior IDMT relays. Time controlbycontrollingamount oI discmovement.Current settingadiustment byuseoI plugbridge Ior selection oI suitable tappingPerlindungan IKRAM 85THERMAL RELAYS THERMAL RELAYS Utilises bending oI a bimetallic strip whenheated by a current Used Ior overload protection because oI itsslow action to heat the bimetallic stripPerlindungan IKRAM 86STATIC RELAYS STATIC RELAYS Utilising electronic components Faster action Better accuracy and consistency Low CT and PT burdens Multiple characteristics Support additional Ieaturescommunication, Iault recording, operating time measurement, current/voltage reading and built-in circuit breaker Iailure protectionPerlindungan IKRAM 87MECHANICAL RELAY MECHANICAL RELAY Respond to pressure, liquid level,temperature, Iluid Ilow, etcPerlindungan IKRAM 88BINAAN GEGANTI BINAAN GEGANTI Hinged Armature Type Induction Cub Magnetic Overload with Plunger (Oil Dash Pot) Attracted Armature (Inst. O/C & E/F)Perlindungan IKRAM 89TIME LAG FUSE TIME LAG FUSE Geganti peringkat awal dimana time lagIuse diselarikan dengan gelong trip coil. Apabila Iius lebur semua arus akan melaluitrip coil dan trip contact akan menutup danmemberi tenaga kepada shunt trip coiluntuk membuka pemutus litar.Perlindungan IKRAM 90Time Lag Fuse Time Lag Fuse Trip Coil Trip CoilPerlindungan IKRAM 91TIME LAG FUSE TIME LAG FUSEPerlindungan IKRAM 92KADARAN TIME LAG FUSE KADARAN TIME LAG FUSESWG 17 15ASWG 18 12.5ASWG 19 10ASWG 21 7.5ASWG 22 6.25ASWG 23 5ASWG 29 2.5APerlindungan IKRAM 93Perlindungan IKRAM 94Perlindungan IKRAM 95GEGANTI OIL DASH POT GEGANTI OIL DASH POT Geganti arus lebih/beban lebih generasi keduaselepas time lag Iuse. Menggunakan minyak silicon sebagai damperuntuk mendapatkan stability. Harganyamurah, bersaizkecil, bolehdipercayai,stabil tetapi tidak begitu tepat dan tatahannya agahrumit dan mengambil masa. Sesuai untukpapansuis utama danpapansuiskecil dimana ketepatan bukanlah perkara kritikal.Perlindungan IKRAM 96OIL DASH POT OIL DASH POTPerlindungan IKRAM 97OIL DASH POT OIL DASH POTPerlindungan IKRAM 98Perlindungan IKRAM 99OIL DASH POT OIL DASH POTPerlindungan IKRAM 100INSTANTENOUS O/C. O/L INSTANTENOUS O/C. O/L Generasi ketiga selepas oil dash pot, terdapat plugsetting bridge untuk memilih tatahan arus, tripcoil, trip contact dan indicator Ilag. Hanya tatahan arus sahaia perlu dibuat Lebih tepat dan mudah ditatah Tidak perlukan minyak Harganya lebih mahal Selalunya ienis attracted armature & plungerPerlindungan IKRAM 101GEGANTI GEGANTISERTAMERTA SERTAMERTAEARTH FAULT EARTH FAULTPerlindungan IKRAM 102INSTANTENOUS EARTH FAULT RELAYPerlindungan IKRAM 103EARTH EARTHFAULT FAULTRELAY RELAYTERMINAL TERMINALPerlindungan IKRAM 104Perlindungan IKRAM 105TERMINAL CONNECTION TERMINAL CONNECTION11 -- 2 TRIP CIRCUIT 2 TRIP CIRCUIT33 -- 44 TRIP CIRCUIT TRIP CIRCUIT55 -- 66 KOSONG KOSONG77 -- 88 KOSONG KOSONG99 -- 10 C.T CONNECTION 10 C.T CONNECTIONPerlindungan IKRAM 106CONNECTION CONNECTIONAT THE BACK AT THE BACKOF THE OF THERELAY RELAYPerlindungan IKRAM 107CONNECTION DIAGRAM CONNECTION DIAGRAMPerlindungan IKRAM 108STATIC STATICOVER OVER- -CURRENT CURRENTRELAY RELAYPerlindungan IKRAM 109STATIC STATICEARTHEARTH FAULT FAULTRELAY RELAYPerlindungan IKRAM 110STATIC STATICO/C & E/F O/C & E/FRELAY RELAYPerlindungan IKRAM 111INSTANTENOUS E/F INSTANTENOUS E/F Jenis yang sama dengan gegantiinstantenous o/c tetapi ia disambungkankepadaalatubaharus yangdipasangpadaneutral busbar untuk mengesan earthIault/earth leakage. Tatahan hanya pada 10 atau 0.5A Hanya satu sahaia diperlukan Jenis attracted armaturePerlindungan IKRAM 112INSTANTENOUS E/F INSTANTENOUS E/F CAG 11Fixed settings up to 20 amps a.cor d.c CAG121040, 2080, 50200 oI 0.5A, 1A or 5A a.c adiustable inseven equal steps, 30120 oI 5A and 80 320 oI 5A a.c CAG13100400, 200800or4001500 oI 0.5A, 1 A or 5APerlindungan IKRAM 113CURRENT SETTING CURRENT SETTING THREE TYPES OF SETTING: Fixed setting (CAG 11) Variable in seven equal steps by plug tapping bridge (CAG 12) Continuously variable by knurled knob against a calibrated scale (CAG 13)Perlindungan IKRAM 114INSTANTANEOUS INSTANTANEOUSE/FE/F RELAY RELAYPerlindungan IKRAM 115TRIP TRIPCONTACT CONTACTTrip coil Trip coilDrop Flag Drop FlagPerlindungan IKRAM 116DROP FLAG DROP FLAGTRIP TRIPINDICATOR INDICATORPerlindungan IKRAM 117CONTINUOUSLY CONTINUOUSLYAD1USTABLE AD1USTABLERELAY RELAYCAG 13 CAG 13Perlindungan IKRAM 118IDMT O/C. O/L IDMT O/C. O/L Mempunyai dua tatahan iaitu arus dan masa: PSM(plug setting multiplier) untuk arus dan TMS (timemultiplier setting / time dial) untuk masa. PSM dalam unit arus (2.5A hingga 10A) atau (50hingga 200) tetapi TMShanyalah satuangka pendharab dari 0 hingga 1. Masa dalam saatdiperolehi dari geraI berdasarkan gandaan aruskerosakan. Selalunya ienis induction disc atau solid staterelay.Perlindungan IKRAM 119PLUG SETTING MULTIPLIER(PSM)/PLUG BRIDGE (O/C RELAY)50 75 100 125 150 175 2002.5A 3.75A 5A 6.25A 7.5A 8.25A 10APerlindungan IKRAM 120IDMT RELAY IDMT RELAY The highest current tap is automaticallyselected when the plug is removed, so thatadiustmentscanbemadeonloadwithoutopen-circuiting the current transIormer It has high torque movement to ensureconsistent timing even under adverseconditions, and a low burden and overshoot AdiustmentoIthe timesetting ismadebyrotatingaknurledmouldeddiscagainst agraduated time multiplier scalePerlindungan IKRAM 121STARTING CURRENT STARTING CURRENT Starting current is 103 to 105 oI currentsetting Closingcurrent is115oIcurrent setting(117 iI Iitted with a mechanical operationindicator)Perlindungan IKRAM 122TIME SETTING TIME SETTING 01.3 seconds at 10 times current settingor 03.0 seconds at 10 times currentsetting Resetting timewith time multiplier at 1.0the resetting time are 4 seconds and 9seconds respectivelyPerlindungan IKRAM 123IDMT IDMTRELAY RELAYPerlindungan IKRAM 124Perlindungan IKRAM 125IDMT RELAY IDMT RELAYPerlindungan IKRAM 1261ENIS 1ENIS- -1ENIS IDMT 1ENIS IDMT Long Time Delay Standby (GDG 12) Inverse Time O/C & E/F (CDG 11) Very Inverse (GDG 13) DeIinite Minimum Time Inverse DeIinite Minimum TimePerlindungan IKRAM 127RELAY RELAYCHARACTERISTIC CHARACTERISTICPerlindungan IKRAM 128INST. & INST. &IDMTIDMT RELAY RELAYPerlindungan IKRAM 129TIME TIMEGRADING GRADINGPerlindungan IKRAM 130GRADING GRADINGMARGIN MARGINPerlindungan IKRAM 131Perlindungan IKRAM 132IDMT E/F IDMT E/F SerupadenganIDMTO/Ctetapidisambungkepadac.t neutral untukperlindunganearthIault atauearthleakage. Hanya satu unit sahaia diperlukan PSM dari 10 hingga 40 dalam 7 step yang sama Lazimnya tatahan TMSialah pada kedudukan 0.1tetapi bukanlah satu kemestian Terdapat Iixed contact dan moving contactPerlindungan IKRAM 133PLUG SETTING MULTIPLIER(PSM)/PLUG BRIDGE (E/F RELAY)10 15 20 25 30 35 400.5A 0.75A 1.0A 1.25A 1.5A 1.75A 2.0APerlindungan IKRAM 134DIRECT & DIRECT &INDIRECT INDIRECTACTING ACTINGPerlindungan IKRAM 135EARTH LEAKAGE RELAYEARTH LEAKAGE RELAY (ELR) (ELR) Untukpenggunaanpapansuis berkadaran100A hingga 400A. Disambungkan kepada Z c.t Tatahanarus dari 30mAhingga 1000mAmelalui micro switch atau terminal yangberlainan Terdapat iuga ienis tatahan arus dan masaPerlindungan IKRAM 136Perlindungan IKRAM 137Perlindungan IKRAM 138Perlindungan IKRAM 139Perlindungan IKRAM 140ELR CONNECTION DIAGRAM ELR CONNECTION DIAGRAMPerlindungan IKRAM 141SINGLE PHASING RELAY SINGLE PHASING RELAY Apabila salah satu Iasa mengalamigangguanbekalanperalatantigaIasaakanmengalami perialanan yang tidak sempurnadan boleh mengakibatkan kerosakan. Geganti ini akan menyebabkan pemutuslitar terbuka iika salah satu Iasanyamengalami gangguan. Selalunya dipasang pada pemula motor tigaIasa yang besar seperti air-condition chiller.Perlindungan IKRAM 142REVERSE PHASE SEQUENCE RELAY REVERSE PHASE SEQUENCE RELAY Sekali sekala turutan Iasa akan terbalikdisebabkanberlakukesilapandalamkeria-keria penyambungan kabel. Motor tiga Iasaakan berpusing terbalik, dan bolehmembahayakan atau merosakan peralatantertentu seperti mesen atau air conditionchiller. Geganti ini akan menyebabkan pemulamotor tidak dapat berIungsi untukmenialankan motor.Perlindungan IKRAM 143UNDERVOLTAGE RELAY UNDERVOLTAGE RELAY Jika voltan bekalan iatuh ketahap yangditetapkan seharusnya bekalan perludiputuskan untuk menghindarkan bahayadan gangguan. Geganti ini akanmenyebabkan pemutus litar akan terbukaiika berlaku keadaan sedemikian.Perlindungan IKRAM 144RESTRICTED E/F RELAY RESTRICTED E/F RELAY Geganti REF dipasang untuk melindungialatubah atau generator iika berlakukerosakan ke bumi didalam alat-alattersebut. Ia hanya melindungi peralatantersebut dan bukannya pemasangan,perlindunganini kadang-kadangdipanggilsebagai unit protection`.Perlindungan IKRAM 145CURRENT SETTING O/C CURRENT SETTING O/C Bergantung kepada kehendak maksimasesuatu pemasangan tetapi nilai tepattatahan pada PSM (Plug Setting multiplier)tidak selalu boleh diperolehi. Oleh itu nilaitertinggi paling hampir dipilih, selalunyapada peringkat commissioning tatahan di setpada 75 atau 3.75A.Perlindungan IKRAM 146CURRENT SETTING E/F CURRENT SETTING E/F Current settinguntukE/Frelaylazimnyaialah pada 10 atau 0.5A Ia tidak bergantung kepada kehendakmaksima sesuatu pemasanganPerlindungan IKRAM 147TIME SETTING O/C & E/F TIME SETTING O/C & E/FSelalunya TMS (Time Multiplier Setting) diset pada kedudukan 0.1 tetapi bukanlah satukemestian, ia perlu dipastikan denganmembuat pengiraan time grading supayahanya pada tatah arus dan masa tertentusahaia geganti tersebut perlu bertindak.Perlindungan IKRAM 148DURATION OF DISTURBANCES DURATION OF DISTURBANCES Overvoltage (microsecond) Short circuit (milisecond) Earth Iault (milisecond) Undervoltage (milisecond) UnderIrequency (second)Perlindungan IKRAM 149TIME TIMECURRENT CURRENTCHARACTERISTIC CHARACTERISTICPerlindungan IKRAM 150TIME TIMECURRENT CURRENTCHARACTERISTIC CHARACTERISTICPerlindungan IKRAM 151TIME TIMECURRENT CURRENTCHARACTERISTIC CHARACTERISTICPerlindungan IKRAM 152U1IAN PRIMARY IN1ECTION U1IAN PRIMARY IN1ECTION Untuk menentukan nisbah alatubah arus Untuk menatah geganti Dibuat sebelum bekalan disambungkan Alat primary iniection test set digunakanPerlindungan IKRAM 153U1IAN SECONDARYU1IAN SECONDARY IN1ECTION IN1ECTION Untuk menguii geganti agar dapat berIungsiseperti apa yang diharapkan Untuk menatah geganti Arusdialirkanteruskepadageganti tanpapenglibatkan alatubah arus Boleh dilakukan tanpa memutuskan bekalan Dilakukan dalam keria-keria senggaraan Menggunakan alatuii secondary iniectiontest setPerlindungan IKRAM 154U1IAN PELANTIKAN U1IAN PELANTIKAN Uiian pelantikan (trip test) dilakukan setelahtatahan di set untuk memastikan sistemperlindungan dan pemutus litar dapat betul-betul berIungsi apabila berlaku keadaantidak normal yang telah ditentukansebelumnya. Ini termasuklah geganti, sistempendawaian, penamatan, gelongshunt tripsecara keseluruhannya.Perlindungan IKRAM 155TRIPPING SUPPLIES TRIPPING SUPPLIES AC Voltagesometimes used to trip ACB,weakness that tripsupplymaybelost atcritical moment DC VoltageMost common type oItrippingpower becauseoIhighreliability.Normally 30V Ior small stations, 110V Iormaior intake points and outdoor substationsand220Vinlargepower stations. BiggerDC system are more expensivePerlindungan IKRAM 156DC TRIPPING SUPPLY DC TRIPPING SUPPLY For 110Vsupply, common to have twobattery chargers and two battery banks.Normally connected in parallel but may beseparated Ior maintenance or boost charge Normally only trip coil per CB but possibleto have two such coils on specialrequirementPerlindungan IKRAM 157INDEX OF INDEX OFPROTECTION PROTECTIONPerlindungan IKRAM 158LIGHTENING LIGHTENINGPROTECTION PROTECTIONPerlindungan IKRAM 159ORANG KOMPETEN ORANG KOMPETEN Orang kompeten yang dibenarkan membuatatau mengendoskan uiian-uiian yang dibuatialah Jurutera Perkhidmatan yang berdaItardengan Suruhaniaya Tenaga dan masih sahuntuk melaksanakan keria tersebut.